SLUSCZ6A
January 2018 – May 2021
BQ25123
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Description (continued)
6
Device Comparison Table
7
Pin Configuration and Functions
8
Specifications
8.1
Absolute Maximum Ratings
8.2
ESD Ratings
8.3
Recommended Operating Conditions
8.4
Thermal Information
8.5
Electrical Characteristics
8.6
Timing Requirements
8.7
Typical Characteristics
9
Detailed Description
9.1
Overview
9.2
Functional Block Diagram
9.3
Feature Description
9.3.1
Ship Mode
9.3.1.1
Ship Mode Entry and Exit
9.3.2
High Impedance Mode
9.3.3
Active Battery Only Connected
9.3.4
Voltage Based Battery Monitor
9.3.5
Sleep Mode
9.3.6
Input Voltage Based Dynamic Power Management (VIN(DPM))
9.3.7
Input Overvoltage Protection and Undervoltage Status Indication
9.3.8
Battery Charging Process and Charge Profile
9.3.9
Dynamic Power Path Management Mode
9.3.10
Battery Supplement Mode
9.3.11
Default Mode
9.3.12
Termination and Pre-Charge Current Programming by External Components (IPRETERM)
9.3.13
Input Current Limit Programming by External Components (ILIM)
9.3.14
Charge Current Programming by External Components (ISET)
9.3.15
Safety Timer and Watchdog Timer
9.3.16
External NTC Monitoring (TS)
9.3.17
Thermal Protection
9.3.18
Typical Application Power Dissipation
9.3.19
Status Indicators ( PG and INT)
9.3.20
Chip Disable ( CD)
9.3.21
Buck (PWM) Output
9.3.22
Load Switch / LDO Output and Control
9.3.23
Manual Reset Timer and Reset Output ( MR and RESET)
9.4
Device Functional Modes
9.5
Programming
9.5.1
Serial Interface Description
9.5.2
F/S Mode Protocol
9.6
Register Maps
9.6.1
Status and Ship Mode Control Register
9.6.2
Faults and Faults Mask Register
9.6.3
TS Control and Faults Masks Register
9.6.4
Fast Charge Control Register
9.6.5
Termination/Pre-Charge and I2C Address Register
9.6.6
Battery Voltage Control Register
9.6.7
SYS VOUT Control Register
9.6.8
Load Switch and LDO Control Register
9.6.9
Push-Button Control Register
9.6.10
ILIM and Battery UVLO Control Register
9.6.11
Voltage Based Battery Monitor Register
9.6.12
VIN_DPM and Timers Register
10
Application and Implementation
10.1
Application Information
10.2
Typical Application
10.2.1
Design Requirements
10.2.2
Detailed Design Procedure
10.2.2.1
Default Settings
10.2.2.2
Choose the Correct Inductance and Capacitance
10.2.2.3
Calculations
10.2.2.3.1
Program the Fast Charge Current (ISET)
10.2.2.3.2
Program the Input Current Limit (ILIM)
10.2.2.3.3
Program the Pre-Charge/Termination Threshold (IPRETERM)
10.2.2.3.4
TS Resistors (TS)
10.2.3
Application Curves
10.2.3.1
Charger Curves
10.2.3.2
SYS Output Curves
10.2.3.3
Load Switch and LDO Curves
10.2.3.4
LS/LDO Output Curves
10.2.3.5
Timing Waveforms Curves
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Device Support
12.1.1
Third-Party Products Disclaimer
12.2
Receiving Notification of Documentation Updates
12.3
Support Resources
12.4
Trademarks
12.5
Electrostatic Discharge Caution
12.6
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
YFP|25
MXBG084M
Thermal pad, mechanical data (Package|Pins)
Orderable Information
sluscz6a_oa
sluscz6a_pm
1
Features
Increases system operation time between charges
Configurable 300-mA buck regulator
700-nA (typical) Iq with buck converter enabled (no load)
Configurable load switch or 100-mA LDO output
Up to 300-mA charge current for fast charging
0.5% accurate battery voltage regulation (configurable from 3.6 V to 4.65 V in 10-mV steps)
Configurable termination current down to
500 µA
Simple voltage based battery monitor
Highly integrated solution with small footprint
2.5 mm x 2.5 mm WCSP package and 6 external components for minimal solution
Push-button wake-up and reset with adjustable timers
Power path management for powering the system and charging the battery
Power path management enables <50-nA Ship Mode battery quiescent current for longest shelf life
Battery charger operates from 3.4 V – 5.5 V
IN
(5.5-V OVP / 20-V tolerant)
Dedicated pins for input current limit, charge current, termination current, and status output
I
2
C communication control
Charge voltage and current
Termination threshold
Input current limit
VINDPM threshold
Timer options
Load switch control
Controls for interrupts for faults and status
System output voltage adjustment
LDO output voltage adjustment