Adam Yager
In my previous blog post, I explored energy efficiency, the first of several trends in building-automation wireless-sensor networks. As a recap, the key trends driving the addition of more sensors in a building-automation system include:
In the second part of this blog series, I’ll go over sensors, which when added to buildings can help protect users and their possessions, notify users and dispatch centers of any security breaches or notify users upon the detection of harmful conditions in the environment.
The two topics of safety and security touch a broad range of building-automation applications, from heating, ventilation and air conditioning (HVAC), to building security, to fire safety systems.
With building security systems, you may find comfort in not just having an alarm system notify authorities of irregular activities, but also giving you status updates about your home or building’s security. Today, a reed switch or digital Hall-effect sensor can help detect discrete door (or window) contact states. A duty-cycled, analog Hall-effect sensor can be used to create a more robust front end, detecting if a secondary magnet is being used to tamper with the system.
When I was a kid, I remember my mom would start driving us to baseball practice, but turn around if she wasn’t sure whether the garage door was open or not. I fear that part of her forgetfulness has rubbed off on me. I tend to forget if I’ve actually locked my doors when I leave my home, so I will often walk back to double-check if my door is locked. With electronic smart locks, you can not only check the lock state, but also lock or unlock the door remotely.
Given the number of smart wireless devices, including wireless door contacts and wireless electronic smart locks, battery life becomes a concern. The smart lock reference design enabling 5 years battery life on 4x AA batteries (TIDA-00757) demonstrates a way to increase the battery life of a 2.4GHz wireless connected electronic lock to roughly five years by using a light-load-efficient DC/DC buck converter. The designer assumed 24 individual lock or unlock events with a 500-ms Bluetooth® Low Energy connection period to determine power consumption and battery life for a 3000 mAh battery capacity.
Detecting the state of locks, doors and windows is very useful from a building-security aspect. Shifting to safety; smoke, toxic gas or even particle monitoring are key concerns for preserving air quality for people.
Beyond audible alarms, being notified of carbon-monoxide (CO) or toxic gas (TIDA-00056) leaks or fires on a remote device can let you know if there are unsafe conditions if you are on vacation, just coming home, or a building owner. In addition to gas and fire detection, particle detection can be used to detect size and concentration for particles including cigarette smoke, dust or pollen. The TI Designs PM2.5 and PM10 Particle Sensor Analog Front-End for Air Quality Monitoring Reference Design (TIDA-00378) can give you a head start for possible ways on how to take optical-based air-quality measurements for smoke, dust or pollen particles.
For a jump-start on connected sensing, be sure to check out these building automation reference designs and the additional resources below.
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2023, Texas Instruments Incorporated