SLLSF01D
December 2017 – June 2022
TLIN2022-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
ESD Ratings - IEC
6.4
Thermal Information
6.5
Recommended Operating Conditions
6.6
Electrical Characteristics
6.7
Switching Characteristics (1)
6.8
Timing Requirements
6.9
Typical Characteristics
Parameter Measurement Information
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
LIN (Local Interconnect Network) Bus
7.3.1.1
LIN Transmitter Characteristics
7.3.1.2
LIN Receiver Characteristics
7.3.1.2.1
Termination
7.3.2
TXD (Transmit Input and Output)
7.3.3
RXD (Receive Output)
7.3.4
VSUP (Supply Voltage)
7.3.5
GND (Ground)
7.3.6
EN (Enable Input)
7.3.7
Protection Features
7.3.8
TXD Dominant Time Out (DTO)
7.3.9
Bus Stuck Dominant System Fault: False Wake Up Lockout
7.3.10
Thermal Shutdown
7.3.11
Under Voltage on VSUP
7.3.12
Unpowered Device and LIN Bus
7.4
Device Functional Modes
7.4.1
Normal Mode
7.4.2
Sleep Mode
7.4.3
Standby Mode
7.4.4
Wake Up Events
7.4.4.1
Wake Up Request (RXD)
7.4.4.2
Mode Transitions
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedures
8.2.2.1
Normal Mode Application Note
8.2.2.2
Standby Mode Application Note
8.2.2.3
TXD Dominant State Timeout Application Note
8.2.3
Application Curves
8.3
Power Supply Recommendations
8.4
Layout
8.4.1
Layout Guidelines
8.4.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DMT|14
MPSS087B
D|14
MPDS177H
Thermal pad, mechanical data (Package|Pins)
DMT|14
QFND638
Orderable Information
sllsf01d_oa
sllsf01d_pm
1
Features
AEC-Q100 Qualified for automotive applications
Temperature: –40°C to 125°C ambient
HBM certification level: ±8 kV
CDM certification level: ±1.5 kV
Compliant to LIN 2.0, LIN 2.1, LIN 2.2, LIN 2.2 A and ISO/DIS 17987–4.2 (See
SLLA491
)
Conforms to SAEJ2602 recommended practice for LIN (See
SLLA491
)
Supports 24 V battery applications
LIN transmit data rate up to 20 kbps.
Wide operating ranges
4 V to 45 V supply voltage
±60 V LIN bus fault protection
Sleep mode: ultra-low current consumption allows wake-up event from:
LIN bus
Local wake up through EN
Power up and down glitch free operation
Protection features:
Under voltage protection on V
SUP
TXD Dominant time out protection (DTO)
Thermal shutdown protection
Unpowered node or ground disconnection failsafe at system level.
Available in SOIC (14) package and leadless VSON (14) Package with improved automated optical inspection (AOI) capability