Product details

PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000005 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 80 Gain (max) (dB) 64 Architecture CMOS Features Fault Detection Vos (offset voltage at 25°C) (typ) (mV) 0.005 Input voltage noise (typ) (µV√Hz) 0.05 Slew rate (typ) (V/µs) 0.6 Iq per channel (typ) (mA) 1.3 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 6 Rating Catalog Operating temperature range (°C) -40 to 125
PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000005 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 80 Gain (max) (dB) 64 Architecture CMOS Features Fault Detection Vos (offset voltage at 25°C) (typ) (mV) 0.005 Input voltage noise (typ) (µV√Hz) 0.05 Slew rate (typ) (V/µs) 0.6 Iq per channel (typ) (mA) 1.3 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 6 Rating Catalog Operating temperature range (°C) -40 to 125
VSON (DRK) 10 12 mm² (4 mm × 3 mm) VSSOP (DGS) 10 14.7 mm² (3 mm × 4.9 mm)
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

Download View video with transcript Video

Similar products you might be interested in

open-in-new Compare alternates
Same functionality with different pin-out to the compared device.
PGA113 ACTIVE Zero-drift, 100-µV offset, 12-nV/√Hz noise, RRO (scope gain) programmable gain amp with 2-ch mux PGA113 is a similar device but not the same functionality, offering wider gain range, 4 calibration channels, 2 channel MUX, and SPI interface

Technical documentation

No results found. Please clear your search and try again.
View all 12
Top documentation Type Title Format options Date
* Data sheet Single-Supply, Auto-Zero Sensor Amplifier with Programmable Gain and Offset datasheet (Rev. B) Dec 22, 2010
Functional safety information PGA308 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML Jun 20, 2024
Application brief Multichannel Analog Input Modules for PLC Equipment Jan 4, 2019
User guide PGA308 User's Guide (Rev. B) Jan 27, 2012
User guide Multi-Cal-PGA308 System User Guide Apr 29, 2011
User guide Multi-Cal-Interface User's Guide Sep 9, 2010
User guide Multi-Cal-Slave User's Guide Sep 9, 2010
User guide Multi-Cal-Cable User's Guide Sep 8, 2010
User guide Multi-Cal-Master User's Guide Aug 22, 2010
User guide Multi-Cal-Test Users Guide Aug 22, 2010
User guide tioScript Editor Users Guide Aug 26, 2008
User guide USB DAQ Platform User's Guide Mar 20, 2008

Design & development

For additional terms or required resources, click any title below to view the detail page where available.

Evaluation board

MULTI-CAL-SYSTEM — Multi-Cal-System Basic Starter Kit

The Multi-Cal-System is a system of evaluation modules and accessories that can be used to calibrate multiple PGA308 sensor modules. The Multi-Cal-System can be configured to calibrate from 8 to 64 PGA308s simultaneously. The key component of the Multi-Cal-System is the Multi-Cal-System Starter (...)

User guide: PDF
Supported products & hardware
In stock
Limit:
??asset.out-of-stock-ti_en_US??
Not available
Evaluation board

PGA308EVM — PGA308 evaluation module

The PGA308EVM key hardware consists of two boards, PGA308 Test Board and USB DAQ Platform. The PGA308 Test Board contains the PGA308, terminal strips for external connections, several jumpers for device configuration, and support circuitry. The PGA308 Test Board can be used to fully test your (...)

User guide: PDF
Supported products & hardware
In stock
Limit:
??asset.out-of-stock-ti_en_US??
Not available
Support software

SBOC256 — PGA308EVM Source Code

Supported products & hardware
Support software

SBOC257 — PGA308EVM Software

Supported products & hardware
Support software

SBOC390 — Multi-Cal-PGA308 System Software

Supported products & hardware
Support software

SBOC391 — Multi-Cal-PGA308 System Source Code

Supported products & hardware
Package Pins CAD symbols, footprints & 3D models
VSON (DRK) 10 Ultra Librarian
VSSOP (DGS) 10 Ultra Librarian

Ordering & quality

Support & training

TI E2E™ forums with technical support from TI engineers

Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

If you have questions about quality, packaging or ordering TI products, see TI support. ​​​​​​​​​​​​​​

Videos