SBAA436 March 2021 REF34-Q1 , REF3425 , REF3425-EP , REF3430 , REF3430-EP , REF3433 , REF3433-EP , REF3440 , REF3440-EP , REF3450 , REF4132 , REF4132-Q1 , REF50 , REF5020-EP , REF5020A-Q1 , REF5025-EP , REF5025-HT , REF5025A-Q1 , REF5030A-Q1 , REF5040-EP , REF5040A-Q1 , REF5045A-Q1 , REF5050-EP , REF5050A-Q1 , REF50E , REF6125 , REF6133 , REF6141 , REF6145 , REF6150 , REF6225 , REF6230 , REF6233 , REF6241 , REF6245 , REF6250 , REF70
Multiple industrial applications, such as grid monitoring and remote field sensors, require instrumentation that operates with high precision over a long period of time. For such use cases with long life times, the Long-Term Drift (LTD) parameter of voltage references, becomes critically important. This application note describes the Long-Term Drift parameter, factors which affect it, how it is measured and gives sample profiles of some of the TI precision voltage references.