SPRACT7 August 2020 TMS320F280021 , TMS320F280021-Q1 , TMS320F280023 , TMS320F280023-Q1 , TMS320F280023C , TMS320F280025 , TMS320F280025-Q1 , TMS320F280025C , TMS320F280025C-Q1 , TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1
The three-phase current sensing with only one dc link shunt resistor can be used for cost sensitive applications. However, special efforts need to reconstruct three-phase current from a dc link current. Moreover, phase current cannot be correctly measured from the single shunt when the active vector duration is less than the minimum measurement time. In order to get dc link current in unmeasurable vector area, a special algorithm for PWM compensation is required. This application report describes how to reconstruct three phase currents with a single current sensor in the inverter dc link. This solution is verified through InstaSPIN™-FOC with MotorControl SDK software platform.