SSZTAQ3 october 2016 ADS1220 , ADS1231 , CSD13381F4 , CSD23381F4 , LP5907 , MSP430G2553 , TS5A21366
Let’s say that you decided to try out a new recipe to surprise someone, but it doesn’t come out quite right. Cooking is an exact science. You could get results eventually through trial and error, but weighing the ingredients would have helped you get it right the first time.
To achieve better results when you cook, you need food processors, ovens and cooktops that integrate weighing capabilities. Guided cooking functions even enable convenient loading of recipes and target weights directly from files or from the internet. Microwave ovens can sense the weight of food automatically and adjust defrosting times accordingly.
The scales in these appliances need to be accurate. Everyone has likely experienced the effect of too much salt or spices in a dish. Accurate weighing of ingredients is critical for the desired outcome, and resolution needs be at or below a gram.
Since most ingredients weighed are less than 1kg, you might assume that 1/1000 resolution is good enough for a resolution of a gram. But for stability, damping and firm standing, the weight gauges are integrated into the feet or fixtures of the appliance. So the total weight of the appliance, food, pots and attachments bear upon the gauges. The total weight can reach 20kg and this maximum determines the dynamic range. Cost-effective wired-or configurations of multiple weighing scale gauges have sensitivities as low as 0.2mV/kg. A stable display requires a peak-to-peak reading noise to be a fraction of a gram. To reliably achieve accuracy less than 1 gram, less than 100nVpp noise and 20 bits of effective resolution are required.
The 1g Resolution over 15kg Range Sub-100nVpp Noise Front-End Reference Design demonstrates the integration of a high-resolution weighing function into smart kitchen appliances. Given the significant levels of switching supply noise and rapid temperature changes, drift and interference are common signal-integrity challenges in appliances. The reference design’s highly integrated precision, 24-bit, analog-to-digital converter (ADC), AC excitation and robust filtering suppress drift and interference and ensure consistent performance in tough environments. Figure 1 depicts the reference design’s block diagram.
The outputs of the strain gauge bridge’s resistive load cells are connected through TS5A21366 low-leakage switches to the ADS1220 precision ADC. The MSP430G2553 microcontroller computes the sliding average of the raw data and controls the front-end operation and chopping of the resistive strain gauge bridge with a configuration of compact CSD23381F4 and CSD13381F4 transistors. The LP5907 LDO and filters robustly suppress noise pickup. This front end demonstrates an effective resolution below a 100nVpp noise readout of resistive load cells, even in the presence of more than ±500mVpp of switching noise.
The test data in the reference design guide demonstrates full performance even when the board is integrated into an operating food processor, supplied directly by a noisy switching supply, and is in close proximity to several noise sources, including the mixer’s running motor. As Figure 2 shows, the noise of the front end is filtering significantly below the 100nV peak-to-peak target over temperature.
The reference design’s accuracy results from the ADS1220 ADC’s benefits, which include:
The low-noise LP5907 LDO’s outstanding high-frequency power-supply rejection ratio – greater 60dB even when supplying 250mA of output current – suppresses switching supply noise in the 100kHz range and other noise pickup very reliably.
Another option for highly cost-constrained applications is to use the ADS1231 precision delta-sigma ADC, especially if chopping at bridge level, suppressing gauge drift, or if multiplexing of multiple gauges is not required.
So if you want to ease getting cooking and baking recipes conveniently right the first time, consider integrating accurate weighing capabilities into your kitchen appliance with our reference design.
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2023, Texas Instruments Incorporated