Product details

Applications Avionics & Defense, Space Number of TXs and RXs 4 TX, 6 RX RF frequency (max) (MHz) 7400 RF frequency (min) (MHz) 5 Number of DUCs per TX 2 Number of DDCs per RX 2 Operating temperature range (°C) -40 to 85 Rating Space
Applications Avionics & Defense, Space Number of TXs and RXs 4 TX, 6 RX RF frequency (max) (MHz) 7400 RF frequency (min) (MHz) 5 Number of DUCs per TX 2 Number of DDCs per RX 2 Operating temperature range (°C) -40 to 85 Rating Space
— (—) See data sheet
  • Request full data sheet
  • Radiation hardness assured AFE7900-SP:
    • Single-event latch up (SEL): 70 MeV-cm2/mg
    • RLAT total ionizing dose (TID): 100 krad(Si)
  • Radiation tolerant AFE7900-SEP:
    • Single-event latch up (SEL): 43 MeV-cm2/mg
    • RLAT total ionizing dose (TID): 30 krad(Si)
  • Quad RF sampling 12GSPS transmit DACs
  • Quad RF sampling 3GSPS receive ADCs
  • Dual RF sampling 3GSPS feedback (auxilliary RX) ADCs
  • RF frequency range: 5MHz - 7.4GHz
  • Maximum RF signal bandwidth:
    • 4TX: 1200MHz or 2TX: 2400MHz
    • 4RX: 1200MHz or 6RX: 600MHz
  • Digital step attenuators (DSA):
    • TX: 40dB range, 0.125dB steps
    • RX or FB: 25dB range, 0.5dB steps
  • Single or dual-band DUC or DDCs for TX and RX
    • 16x NCOs per TX or RX and FB
  • Optional internal PLL or VCO for DAC or ADC clocks
  • External clock at DAC or ADC sample rate
  • SYSREF alignment detector
  • SerDes data interface:
    • JESD204B and JESD204C compatible
    • 8 SerDes transceivers up to 29.5Gbps
    • Subclass 1 multi-device synchronization
  • Supports aerospace and defense applications
    • Controlled baseline
    • One fabrication, assembly, and test site
    • Product traceability
    • Extended product life cycle
    • Radiation lot acceptance Test (RLAT) (AFE7900-SEP/SP only)
    • Meets ASTM E595 out-gassing specification
    • Production burn-in (AFE7900-SP only)
  • This device contains non-encapsulated chip-caps with tin (Sn) finish of >97% purity. See reliability report for more information.
  • Request full data sheet
  • Radiation hardness assured AFE7900-SP:
    • Single-event latch up (SEL): 70 MeV-cm2/mg
    • RLAT total ionizing dose (TID): 100 krad(Si)
  • Radiation tolerant AFE7900-SEP:
    • Single-event latch up (SEL): 43 MeV-cm2/mg
    • RLAT total ionizing dose (TID): 30 krad(Si)
  • Quad RF sampling 12GSPS transmit DACs
  • Quad RF sampling 3GSPS receive ADCs
  • Dual RF sampling 3GSPS feedback (auxilliary RX) ADCs
  • RF frequency range: 5MHz - 7.4GHz
  • Maximum RF signal bandwidth:
    • 4TX: 1200MHz or 2TX: 2400MHz
    • 4RX: 1200MHz or 6RX: 600MHz
  • Digital step attenuators (DSA):
    • TX: 40dB range, 0.125dB steps
    • RX or FB: 25dB range, 0.5dB steps
  • Single or dual-band DUC or DDCs for TX and RX
    • 16x NCOs per TX or RX and FB
  • Optional internal PLL or VCO for DAC or ADC clocks
  • External clock at DAC or ADC sample rate
  • SYSREF alignment detector
  • SerDes data interface:
    • JESD204B and JESD204C compatible
    • 8 SerDes transceivers up to 29.5Gbps
    • Subclass 1 multi-device synchronization
  • Supports aerospace and defense applications
    • Controlled baseline
    • One fabrication, assembly, and test site
    • Product traceability
    • Extended product life cycle
    • Radiation lot acceptance Test (RLAT) (AFE7900-SEP/SP only)
    • Meets ASTM E595 out-gassing specification
    • Production burn-in (AFE7900-SP only)
  • This device contains non-encapsulated chip-caps with tin (Sn) finish of >97% purity. See reliability report for more information.

The AFE7900-x is a high performance, wide bandwidth multi-channel transceiver, integrating four RF sampling TX chains, four RF sampling RX chains and two RF sampling FB chains (six RF sampling ADCs total). With operation up to 7.4GHz, this device enables direct RF sampling in the L, S and C-band frequency ranges without the need for additional frequency conversions stages. This improvement in density and flexibility enables high-channel-count, multi-mission systems.

The TX signal paths support interpolation and digital up conversion options that deliver up to 1200MHz of signal bandwidth for four TX or 2400MHz for two TX. The output of the DUCs drives a 12GSPS DAC with a mixed mode output option to enhance 2nd Nyquist operation. The DAC output includes a variable gain amplifier (TX DSA) with 40dB range and 1dB analog and 0.125dB digital steps.

Each receiver chain includes a 25dB range DSA (Digital Step Attenuator), followed by a 3GSPS ADC. Each receiver channel has an analog peak power detector and various digital power detectors to assist an external or internal autonomous automatic gain controller, and RF overload detectors for device reliability protection. Flexible decimation options provide optimization of data bandwidth up to 1200MHz for four RX without FB paths or 600MHz with two FB paths (1200MHz IBW per FB ADC).

The AFE7900-x is a high performance, wide bandwidth multi-channel transceiver, integrating four RF sampling TX chains, four RF sampling RX chains and two RF sampling FB chains (six RF sampling ADCs total). With operation up to 7.4GHz, this device enables direct RF sampling in the L, S and C-band frequency ranges without the need for additional frequency conversions stages. This improvement in density and flexibility enables high-channel-count, multi-mission systems.

The TX signal paths support interpolation and digital up conversion options that deliver up to 1200MHz of signal bandwidth for four TX or 2400MHz for two TX. The output of the DUCs drives a 12GSPS DAC with a mixed mode output option to enhance 2nd Nyquist operation. The DAC output includes a variable gain amplifier (TX DSA) with 40dB range and 1dB analog and 0.125dB digital steps.

Each receiver chain includes a 25dB range DSA (Digital Step Attenuator), followed by a 3GSPS ADC. Each receiver channel has an analog peak power detector and various digital power detectors to assist an external or internal autonomous automatic gain controller, and RF overload detectors for device reliability protection. Flexible decimation options provide optimization of data bandwidth up to 1200MHz for four RX without FB paths or 600MHz with two FB paths (1200MHz IBW per FB ADC).

Download View video with transcript Video

See the full data sheet and other design resources for the general-purpose AFEs. Request now

Technical documentation

No results found. Please clear your search and try again.
View all 2
Top documentation Type Title Format options Date
* Data sheet AFE7900-EP/SEP/SP: 4T6R, 5MHz to 7.4GHz, 1.2GHz IBW, RF-Sampling AFE with 12GSPS DACs and 3GSPS ADCs datasheet PDF | HTML Aug 13, 2026
* Radiation & reliability report AFE7900-SEP Radiation High Performance, Wide Bandwidth Multi-Channel Transceiver TID Report (Rev. A) Jun 30, 2026

Design & development

For additional terms or required resources, click any title below to view the detail page where available.

Package Pins CAD symbols, footprints & 3D models
— (—)

Ordering & quality

Support & training

TI E2E™ forums with technical support from TI engineers

Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

If you have questions about quality, packaging or ordering TI products, see TI support. ​​​​​​​​​​​​​​

Videos